FIGURE 13 –
Remote Control
90-1636
Model 76 Control
Model 76 LCD Display
Solid ON:
Control On
Blinking ON:
Dehumidifying
Measured Humidity
in Remote Location
or
Dryness Level Setting
Control On/Off
Dryness Level
Control must be
ON to adjust.
SET: Shows when
dryness level
setting displayed
or being changed.
Does not display
when setting
dryness level
OFF: Control Off
TEST MODE
1. Press and hold the ON button for 5 seconds to enter Test Mode.
a. Verify the measured humidity is displayed on the Model 76 screen.
b. Verify dehumidifier turns on, and ON blinks on the Model 76 screen.
c. Verify the
*
is displayed on the Model 76 screen when wired as a REMOTE CONTROL.
2. After 5 minutes or after pressing the OFF button, the control will enter Off mode.
a. Verify the dehumidifier turns off.
HUMIDITY/ DRYNESS LEVEL SETTING
•ThecontrolmustbeONtoadjustthehumidityordrynesslevelsetting.
•The (up) and (down) buttons are used to increase or decrease the setting.
•ThefirstpressofeitherbuttonwilldisplaythecurrentsettingandSET on the LCD display.
•Eachsubsequentpushoftheupordownbuttonswillchangethesettingby1%or1dryness
level.
•Ifabuttonishelddown,thesettingwillcontinuallychangeby1%or1drynesslevelevery
1/2 second for as long as the button is pressed.
•ThecontrolwillreturntoNormalMode,displayingthemeasuredhumidity,5secondsafter
the last button press/release.
OFFSET
When the Model 76 is installed as an EXTERNAL
CONTROL, an offset can be applied to the humidity
reading to avoid discrepancies with other humidity
measuring devices in the home. Allow 48 hours for
the control to acclimate before applying an offset. The
control must be ON to enter the Offset screen.
NOTE: This feature is not available when the control
is installed as a REMOTE CONTROL.
•PressandholdtheOFFbuttonfor5secondsto
enter the Offset screen.
•The
buttons can be used to set an offset
value between -5% RH and +5% RH.
•ThecontrolwillreturntoNormalMode,displaying
the measured humidity, 5 seconds after the last
button press/release.
FIGURE 14 – Offset Screen