IMPORTANT SAFETY INFORMATION
WARNING:
Always turn off power at the main power source by unscrewing
fuse or switching circuit breaker to the off position before installing,
removing, cleaning, or servicing thermostat.
Read all of the information in this manual before installing or
programming this thermostat.
This is a 24V AC low-voltage thermostat. Do not install on voltages
higher than 30V AC.
All wiring must conform to local and national building and electrical
codes and ordinances.
Do not short (jumper) across terminals on the gas valve or at the
system control to test installation. This will damage the thermostat
and void the warranty.
1
2 Heat / 2 Cool Digital
Heat Pump
MODEL 8336
User’s Manual
Installation and
Operation
ELECTRONIC THERMOSTATS
®
Vedere la pagina 0
1 2 3 4 5 6 ... 15 16

Sommario

Pagina 1 - MODEL 8336

IMPORTANT SAFETY INFORMATIONWARNING:• Always turn off power at the main power source by unscrewingfuse or switching circuit breaker to the off positio

Pagina 2 - Replacing Existing Thermostat

10RY1OBG EW2LCY2APRILAIRE MODEL 8336 HEAT PUMP THERMOSTATRYOGEW2LCW3CARRIER LOW VOLTAGE TERMINAL BOARDAPRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT CONVER

Pagina 3 - Figure 2

11RY1OBG EW2LCY2APRILAIRE MODEL 8336 HEAT PUMP THERMOSTATRYOGW1W2XCCOMFORTMAKER LOW VOLTAGE TERMINAL BOARDAPRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT CO

Pagina 4 - Mounting Holes

12RY1OBG EW2LCY2APRILAIRE MODEL 8336 HEAT PUMP THERMOSTATRYBGEW2LXBRHEEM/RUUDLOW VOLTAGE TERMINAL BOARDAPRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT CONVE

Pagina 5 - °F/°C Switch

13RY1OBG EW2LCY2APRILAIRE MODEL 8336 HEAT PUMP THERMOSTATRYOGX2W-UBWEATHERTRON LOW VOLTAGE TERMINAL BOARDAPRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT CON

Pagina 6 - Operation

14RY1OBG EW2LCY2APRILAIRE MODEL 8336 HEAT PUMP THERMOSTATRYOGEW1LCTLENNOX LOW VOLTAGE TERMINAL BOARDAPRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT CONVERSI

Pagina 7 - To Test Thermostat

15RY1OBG EW2LCY2APRILAIRE MODEL 8336 HEAT PUMP THERMOSTATR-VRY1OFEW1XLENNOX LOW VOLTAGE TERMINAL BOARDAPRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT CONVER

Pagina 8 - Troubleshooting

Limited WarrantyYour Research Products Corporation Aprilaire®Thermostat unit is expresslywarranted for two (2) years from date of installation to be f

Pagina 9

Features• Multi Stage heating and cooling control.• Zone system compatible as a master thermostat.• Multi-Colored LED indicators for system status.• L

Pagina 10 - Wiring Diagrams

4. After labeling wires, remove wires from terminals.5. Remove existing thermostat base from wall.6. Refer to the following section for instructions o

Pagina 11 - CYC SERIES HEAT PUMP SYSTEMS

5. Place thermostat against the wall at desired location. Make surewires will feed through opening on base of thermostat. 6. Mark placement of mountin

Pagina 12 - HEAT PUMP SYSTEMS

11. Connect wires to terminal strip. Refer to wiring diagrams on otherside of this sheet. Make sure wire connections are secure.12. Put the °F/°C swit

Pagina 13 - TO WEATHERTRON HEAT PUMPS

OperationSetting or Changing the Setpoint Temperature1. Press either the or button. The display will show the current temperature setpoint.2. Press

Pagina 14 - CB19 HEAT PUMP SYSTEMS

7To Test ThermostatWARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GASVALVE OR SYSTEM CONTROL TO TEST OPERATION. THIS WILL DAMAGETHE THERMOSTAT AND